Integrated digital and analog inputs/outputs
       
Signal boards for direct use in a controller
       
Signal modules for expansion of controllers by input/output channels
       
Communication modules for expansion of controllers with additional communications interfaces
       
Accessories, e.g. power supply, switch module or SIMATIC Memory Card
   
The miniature controller that offers maximum automation at minimum cost.
   
Extremely simple installation, programming and operation.
   
Large-scale integration, space-saving, powerful.
   
Suitable for small to medium-size automation engineering applications.
   
Can be used both for simple controls and for complex automation tasks.
   
All CPUs can be used in stand-alone mode, in networks and within distributed structures.
   
Suitable for applications where programmable controllers would not have been economically viable in the past.
   
With exceptional real-time performance and powerful communication options.

go up
Application

The SIMATIC S7-1200 is the controller for open-loop and closed-loop control tasks in mechanical equipment manufacture and plant construction. It combines maximum automation and minimum cost.

Due to the compact modular design with a high performance at the same time, the SIMATIC S7-1200 is suitable for a wide variety of automation applications. Its range of use extends from the replacement of relays and contactors up to complex automation tasks in networks and within distributed structures.

The S7-1200 also increasingly opens up areas for which special electronics was previously developed for economical reasons.

Application examples include, for example:

   
Placement systems
   
Conveyor systems
   
Elevators and escalators
   
Material transportation equipment
   
Metalworking machinery
   
Packaging machines
   
Printing machines
   
Textile machines
   
Mixing systems
   
Freshwater treatment plants
   
Wastewater treatment plants
   
External displays
   
Electricity distribution stations
   
Room temperature control
   
Heating/cooling system control
   
Energy management
   
Fire protection systems
   
Air conditioning
   
Lighting control
   
Pump control
   
Security/access control systems

go up
Design

The SIMATIC S7-1200 family consists of the following modules:

   
Compact controllers with graded performances in different versions as wide-range AC or DC controllers.
   
Signal boards (analog and digital) for low-cost modular controller expansion directly on the CPU, with retention of the mounting space.
   
Different digital and analog signal modules.
   
Communication modules (RS232/RS485) for communication via point-to-point connection.
   
Communication modules for connection of the controller as a PROFIBUS DP master or PROFIBUS DP slave.
   
Communication processors for connection of the controller to mobile phone networks.
   
Ethernet switch with 4 ports for implementation of many different network topologies
   
PS 1207 stabilized power supply units, line voltage 115/230 V AC, rated voltage 24 V DC

Mechanical features

   
Rugged, compact plastic enclosure
   
Easily accessible connection and control elements, protected by front flaps
   
Removable connection terminals, also for analog or digital expansion modules

Device features

   
International standards:
   
SIMATIC S7-1200 complies with the standards according to VDE, UL, CSA and FM (Class I, Category 2; Danger zone groups A, B, C and D, T4A). The quality management system used during production is certified according to ISO 9001.

Communication

The SIMATIC S7-1200 is equipped with different communication mechanisms:

   
Integrated PROFINET IO Controller interface
   
Point-to-point connection via communication modules

PROFINET interface

The integral PROFINET interface permits communication with:

   
Programming device
   
HMI devices
   
Other SIMATIC controllers
   
PROFINET IO automation components

The following protocols are supported:

   
TCP/IP
   
ISO-on-TCP
   
S7 communication

The following can be connected:

   
Field PG programming device and PCs via standard CAT5 cable.

Connection between PG and CPU of SIMATIC S7-1200

   
SIMATIC HMI Basic Panels

Connection between Basic Panel and CPU of SIMATIC S7-1200

   
Further SIMATIC S7-1200 controllers

Connection of several devices via CSM 1277 Ethernet switch

Point-to-point interface, freely-programmable interface mode

Communication modules permit communication via point-to-point connections. The RS232 and RS485 physical transmission media are used. Data transmission is carried out in the "Freeport" mode of the CPU. A user-specific, bit-oriented communication protocol is used (e.g. ASCII protocol, USS, or Modbus).

Any terminal equipment with a serial interface can be connected, e.g. drives, printers, bar code readers, modems, etc.

Point-to-point connection via CM 1241 in programmable interface mode
go up
Function

The S7-1200 is characterized by:

   
Extremely simple starter solution:
   
Special starter packages and introductions facilitate familiarization.
   
Uncomplicated operation:
   
Powerful standard commands which are simple to use, together with the user-friendly programming software, reduce the programming overhead to a minimum.
   
Exceptional real-time characteristics:
   
Special interrupt functions, fast counters, and pulse outputs permit use even with time-critical processes.

The SIMATIC S7-1200 meets national and international standards:

   
UL 508
   
CSA C22.2 No. 142
   
FM Class I, div. 2, group A, B, C, D; T4A Class I, Zone 2, IIC, T4
   
VDE 0160
   
EN 61131-2
   
Requirements of the EMC directive in accordance with EN 50081-1, 50081-2 and 50082-2