S7-1200
Integrated digital and analog inputs/outputs
Signal boards
for direct use in a controller
Signal modules
for expansion of controllers by input/output channels
Communication
modules for expansion of controllers with additional communications interfaces
Accessories,
e.g. power supply, switch module or SIMATIC Memory Card
The miniature controller that offers
maximum automation at minimum cost.
Extremely simple installation,
programming and operation.
Large-scale integration, space-saving,
powerful.
Suitable for small to medium-size
automation engineering applications.
Can be used both for simple controls
and for complex automation tasks.
All CPUs can be used in stand-alone
mode, in networks and within distributed structures.
Suitable for applications where
programmable controllers would not have been economically viable in the past.
With exceptional real-time performance
and powerful communication options.
go up
Application
The SIMATIC S7-1200 is the controller for open-loop and closed-loop control tasks in mechanical
equipment manufacture and plant construction. It combines maximum automation and minimum
cost.
Due to the compact modular design with a high performance at
the same time, the SIMATIC S7-1200 is suitable for a wide variety of automation applications. Its range of use extends
from the replacement of relays and contactors up to complex automation tasks in networks and
within distributed structures.
The S7-1200 also increasingly opens up areas for which
special electronics was previously developed for economical reasons.
Application examples include, for example:
Placement systems
Conveyor systems
Elevators and escalators
Material transportation equipment
Metalworking machinery
Packaging machines
Printing machines
Textile machines
Mixing systems
Freshwater treatment plants
Wastewater treatment plants
External displays
Electricity distribution stations
Room temperature control
Heating/cooling system control
Energy management
Fire protection systems
Air conditioning
Lighting control
Pump control
Security/access control systems
go up
Design
The SIMATIC S7-1200 family consists of the following
modules:
Compact controllers with graded
performances in different versions as wide-range AC or DC controllers.
Signal boards (analog and digital) for
low-cost modular controller expansion directly on the CPU, with retention of the mounting space.
Different digital and analog signal
modules.
Communication modules (RS232/RS485) for
communication via point-to-point connection.
Communication modules for connection of
the controller as a PROFIBUS DP master or PROFIBUS DP slave.
Communication processors for connection
of the controller to mobile phone networks.
Ethernet switch with 4 ports for
implementation of many different network topologies
PS 1207 stabilized power supply units,
line voltage 115/230 V AC, rated voltage 24 V DC
Mechanical features
Rugged, compact plastic enclosure
Easily accessible connection and
control elements, protected by front flaps
Removable connection terminals, also
for analog or digital expansion modules
Device features
International standards:
SIMATIC S7-1200 complies with the
standards according to VDE, UL, CSA and FM (Class I, Category 2; Danger zone
groups A, B, C and D, T4A). The quality management system used during
production is certified according to ISO 9001.
Communication
The SIMATIC S7-1200 is equipped with different
communication mechanisms:
Integrated PROFINET IO Controller
interface
Point-to-point connection via
communication modules
PROFINET interface
The integral PROFINET interface permits communication with:
Programming device
HMI devices
Other SIMATIC controllers
PROFINET IO automation components
The following protocols are supported:
TCP/IP
ISO-on-TCP
S7 communication
The following can be connected:
Field PG programming device and PCs via
standard CAT5 cable.
Connection between PG and CPU of SIMATIC S7-1200
SIMATIC HMI Basic Panels
Connection between Basic Panel and CPU of SIMATIC S7-1200
Further SIMATIC S7-1200 controllers
Connection of several devices via CSM 1277 Ethernet switch
Point-to-point interface, freely-programmable interface
mode
Communication modules permit communication via
point-to-point connections. The RS232 and RS485 physical transmission media are
used. Data transmission is carried out in the "Freeport" mode of the CPU. A
user-specific, bit-oriented
communication protocol is used (e.g. ASCII protocol, USS, or Modbus).
Any terminal equipment with a serial interface can be
connected, e.g. drives, printers, bar code readers, modems, etc.
Point-to-point connection via CM 1241 in programmable
interface mode
go up
Function
The S7-1200 is characterized by:
Extremely simple starter solution:
Special starter packages and
introductions facilitate familiarization.
Uncomplicated operation:
Powerful standard commands which are
simple to use, together with the user-friendly programming software, reduce
the programming overhead to a minimum.
Exceptional real-time characteristics:
Special interrupt functions, fast
counters, and pulse outputs permit use even with time-critical processes.
The SIMATIC S7-1200 meets national and international
standards:
UL 508
CSA C22.2 No. 142
FM Class I, div. 2, group A, B, C, D;
T4A Class I, Zone 2, IIC, T4
VDE 0160
EN 61131-2
Requirements of the EMC directive in
accordance with EN 50081-1, 50081-2 and 50082-2