Inverter
The inverter is especially characterized by its customer-oriented performance and ease-of-use. Its large mains voltage range enables it to be used all over the world.
Design
The MICROMASTER 440 has a modular design. The operator panels and the modules can be easiliy exchanged.
International standards
- The MICROMASTER 440 inverter complies with the requirements of the EU low-voltage guideline.
- The MICROMASTER 440 inverter has the CE marking.
- Acc. to UL and c UL certified
- c-tick
Main characteristics
- Easy, guided start-up
- Modular construction allows maximum configuration flexibility
- Six programmable isolated digital inputs
- Two scaleable analog inputs (0 V to 10 V, 0 mA to 20 mA) can also be used as a 7th/8th digital input
- Two programmable analog outputs (0 mA to 20 mA)
- Three programmable relay outputs (30 V DC/5 A, resistive load; 250 V AC/2 A, inductive load)
- Low-noise motor operation thanks to high pulse frequencies, adjustable (observe derating if necessary)
- Protection for motor and inverter
Options (overview)
- EMC filter, Class A/B
- LC filter and sinusoidal filter
- Line commutating chokes
- Output chokes
- Gland plates
- Basic Operator Panel (BOP) for parameterizing the inverter
- Plain text Advanced Operator Panel (AOP) with multilanguage display
- Plain text Asian Advanced Operator Panel (AAOP) with Chinese and English display
- Plain text Cyrillic Advanced Operator Panel (CAOP) with Cyrillic, German and English display
- Communication modules
- PROFIBUS
- DeviceNet
- CANopen
- Pulse encoder evaluation module
- PC connection kits
- Mounting kits for installing the operator panels in the control cabinet doors
- PC start-up tools, executable under Windows 98/NT/2000/XP Professional
- TIA integration with Drive ES
Mechanical features
- Modular design
- Operating temperature
- 0.12 kW to 75 kW: -10 °C to +50 °C (+14 °F to +122 °F)
- 90 kW to 200 kW: 0 °C to +40 °C (+32 °F to +104 °F)
- Compact housing as a result of high power density
- Easy cable connection, mains and motor connections are separated for optimum electromagnetic compatibility
- Detachable operator panels
- Screwless control terminals on detachable I/O board
Performance features
- Latest IGBT technology
- Digital microprocessor control
- High-quality Vector Control system
- Flux Current Control (FCC) for improved dynamic response and optimized motor control
- Linear V/f characteristic
- Quadratic V/f characteristic
- Multipoint characteristic (programmable V/f characteristic)
- Torque control
- Flying restart
- Slip compensation
- Automatic restart following mains failure or fault
- User-definable function blocks for logic and arithmetic operations
- Kinetic buffering
- Positioning ramp down
- High-grade PID controller for simple internal process control (autotuning)
- Programmable acceleration/deceleration, 0 s to 650 s
- Ramp smoothing
- Fast Current Limit (FCL) for trip-free operation
- Fast, repeatable digital input response time
- Fine adjustment using two high-resolution 10-bit analog inputs
- Compound braking for controlled rapid braking
- Integrated brake chopper (only for 0.12 kW to 75 kW inverters)
- Four skip frequencies
- Removable “Y” capacitor for use on IT mains supplies (with non-grounded mains supplies, the “Y” capacitor must be removed, and an output choke installed)
Protection features
- Overload capability
- CT mode
0.12 kW to 75 kW:
Overload current 1.5 x rated output current (i.e. 150 % overload capability) for 60 s, cycle time 300 s,
and 2 x rated output current (i.e. 200 % overload capability) for 3 s, cycle time 300 s
90 kW to 200 kW:
Overload current 1.36 x rated output current (i.e. 136 % overload capability) for 57 s, cycle time 300 s,
and 1.6 x rated output current (i.e. 160 % overload capability) for 3 s, cycle time 300 s - VT mode
5.5 kW to 90 kW:
Overload current 1.4 x rated output current (i.e. 140 % overload capability) for 3 s,
and 1.1 x rated output current (i.e. 110 % overload capability) for 60 s, cycle time 300 s
110 kW to 250 kW:
Overload current 1.5 x rated output current (i.e. 150 % overload capability) for 1 s,
and 1.1 x rated output current (i.e. 110 % overload capability) for 59 s, cycle time 300 s - Overvoltage/undervoltage protection
- Inverter overtemperature protection
- Special direct connection for PTC or KTY to protect the motor
- Earth fault protection
- Short-circuit protection
- I 2 t motor thermal protection
- Locked motor protection
- Stall prevention
- Parameter interlock
+ نوشته شده در شنبه بیست و پنجم آذر ۱۳۹۱ ساعت 17:57 توسط س.دمی زاده
|
به نام خدا